ข้อมูลจำเพาะทางเทคนิค (Technical Specification) ของ Mecair – Filter Failure Alarm
DOWNLOAD DATA SHEET
FILTEROPERATIONAL RANGE
- Suitable for a wide range of dust collectors designs and configurations
- Dust level response: <1mg/m3 to 500mg/ m3 (<0.028 mg/ft3 to 14 mg/ft3)
- Flue gas velocity from 4m/sec
- Flue gas temperature up to 240°C (464°F)
- Ambient temperature from -20°C to +50°C (-4°F to +122°F)
- Duct sizes from 0.5m
- Hazardous area ATEX II 3GD
- US-EPA MACT compliant
PROCESS AND APPLICATION CONDITIONS
Stack temperature range B
|
–20 to 240°C (–4 to 465°F)
|
SENSOR – KEY DATA
|
|
Flue gas velocity
|
4 m/s
|
Dust level response
|
<1 to 500 mg/m³ (dependent upon application)
|
Application conditions
|
Suitable for measurement in non-condensing šue gases.
|
Hazardo us zone classification
|
ATEX Zones 2 (Gas) and 22 (Dust)
|
ENVIRONMENTAL INFORMATION
|
|
Altitude category
|
max. 2,000 m (6,500 ft.)
|
SENSOR SPECIFICATION
|
|
FILTER FAILURE ALARM MONITOR
|
|
Sensor variant
|
Standard sensor: 0–240°C (up to 465°F)
|
Probe rod material
|
316 Stainless Steel, PTFE (insulator)
|
Weight
|
900g (2 lb), excl. rod
|
Cable entries
|
2× M16 cable glands (one blanked)
|
ENCLOSURE
|
|
Ambient temperature range B
|
20 to +50°C (–4 to 130°F)
|
Protection rating
|
IP65
|
Material
|
Die-cast aluminium LM6M (epoxy coated)
|
POWER REQUIREMENTS
|
|
Power supply voltage
|
24 V DC (from the control unit)
|